Technical features of medical connectors and cables:
1. Shell material of medical connectors and cables: PEI/PSU
2. Temperature range of medical connectors and cables: -50°/+170°
3. Mating Cycles of medical connectors and cables: ≤ 1000
4. Pin material of medical connectors and cables :   Brass,Gold plate.
5. Waterproof grade of medical connectors and cables: IP50/IP64
6. Shell diameter: 14mm
7. End connection: welding, pressing and PCB board connection
8. High temperature disinfection: PEI shell, high temperature resistance disinfection
9. The plastic core and pin is specially designed for touch protection
The light was
11. Low plugging force
12. The non-magnetic
Resistant to high temperature disinfection and corrosion
14. Chamfering of insulators can prevent accidental insertion

Electrical Parameters:

Pin   Number

Max.AWG/mm²

Test   Voltage(KV)

Rated  Current(A)

2

20/0.5

1.9

10

3

20/0.5

1.9

8

4

22/0.38

1.9

7

5

22/0.38

1.6

6

6

26/0.15

1.6

5

7

26/0.15

1.6

5

8

26/0.15

1.6

5

9

28/0.08

1.35

3

10

28/0.08

1.35

2

14

28/0.08

1.35

2


 

Feature

                 Parameter

 

     Standard

       PEEK

       PSU

    PPSU

Color

Natural color/biege

White/gray

Cream color


Cycle times

5000 times

5000 times

5000 times

IEC60512-5/9a

Temperature



Temperature  range

-50/+250

-50/+150

-50/+180


Wet sterilizatoin

200 times

20 times

100 times

IEC60601-1/44.7

Decay resistance

Very good

common

good



GB10151-1988  Medical X-ray equipment high-voltage cable plug socket technical conditions
Gb10793-2000  Safety requirements for electrocardiogram machines for medical electrical equipment
GB14710-1993  Environmental requirements and test methods for medical electrical equipment
GB/T15953-1995  Instrument for measuring aural acoustic impedance admittance IEC 1027:1991, Instrument for measuring aural acoustic impedance
Yy0046-91  Medical Gamma camera technical parameters
Yy0042-91  high frequency jet ventilator
Yy0055-2002  Light curing machine
Yy0061-91  Specific electromagnetic wave therapeutic apparatus
Yy0089-92  Special safety requirements for patient monitoring systems
Yy0107-93  Type A pulse reflection ultrasonic diagnostic equipment
Yy0108-93  Type M pulse reflection ultrasonic diagnostic equipment
Yy0164-94  Ultrasonic Doppler fetal monitor
Yy0322-2000  High frequency electrocautery therapy instrument
Yy0448-2003  Ultrasonic Doppler fetal heart rate meter
Yy91079-99  Ecg monitor
Yy91090-99  ultrasonic therapy equipment
Yy91093-91094-99  intermediate frequency electrotherapy instrumen


The last  prodcut:Medical high-definition camera system cable ,circular plastic 14pin connector

Circular Connector
M5 connector
M8 connector
M12 connector
M16 connector
M23 connector
Circular connector cable
Push-pull connector
B series
K series
F series
S series
E series
P series
Retangular connector
Circular photoelectric hybrid
Contact us
Hotline:+86 755-23063852
Tel:+86-755-23063852
Email:chenliang@tobeest.com
Address:6/F,Building B,DongMingXing Industrial Park,LiYuHe...
follow us

follow us

Copyright©2018 Shenzhen TOBEEST Co., Ltd. Copyright©2018 Shenzhen TOBEEST Co., Ltd. 技术支持:洛壹网络