Technical features of Medical equipment instrument connector:
1. Shell material: PEI/PSU
2. Temperature range: -50°/+170°
3. Mating Cycles: ≤ 1000
4. Pin material: Brass,Gold plate.
5. Waterproof grade: IP50/IP64
6. Shell diameter: 14mm
7. End connection: welding, pressing and PCB board connection
8. High temperature disinfection: PEI shell, high temperature resistance disinfection
9. The plastic core and pin is specially designed for touch protection
The light was
11. Low plugging force
12. The non-magnetic
Resistant to high temperature disinfection and corrosion
14. Chamfering of insulators can prevent accidental insertion
Electrical Parameters of Medical equipment instrument connector:
Pin Number | Max.AWG/mm² | Test Voltage(KV) | Rated Current(A) |
2 | 20/0.5 | 1.9 | 10 |
3 | 20/0.5 | 1.9 | 8 |
4 | 22/0.38 | 1.9 | 7 |
5 | 22/0.38 | 1.6 | 6 |
6 | 26/0.15 | 1.6 | 5 |
7 | 26/0.15 | 1.6 | 5 |
8 | 26/0.15 | 1.6 | 5 |
9 | 28/0.08 | 1.35 | 3 |
10 | 28/0.08 | 1.35 | 2 |
Feature | Parameter |
Standard | ||
PEEK | PSU | PPSU | ||
Color | Natural color/biege | White/gray | Cream color | |
Cycle times | >5000 times | >5000 times | >5000 times | IEC60512-5/9a |
Temperature | ||||
Temperature range | -50℃/+250℃ | -50℃/+150℃ | -50℃/+180℃ | |
Wet sterilizatoin | >200 times | >20 times | >100 times | IEC60601-1/44.7 |
Decay resistance | Very good | common | good |
GB10151-1988 Medical X-ray equipment high-voltage cable plug socket technical conditions
Gb10793-2000 Safety requirements for electrocardiogram machines for medical electrical equipment
GB14710-1993 Environmental requirements and test methods for medical electrical equipment
GB/T15953-1995 Instrument for measuring aural acoustic impedance admittance IEC 1027:1991, Instrument for measuring aural acoustic impedance
Yy0046-91 Medical Gamma camera technical parameters
Yy0042-91 high frequency jet ventilator
Yy0055-2002 Light curing machine
Yy0061-91 Specific electromagnetic wave therapeutic apparatus
Yy0089-92 Special safety requirements for patient monitoring systems
Yy0107-93 Type A pulse reflection ultrasonic diagnostic equipment
Yy0108-93 Type M pulse reflection ultrasonic diagnostic equipment
Yy0164-94 Ultrasonic Doppler fetal monitor
Yy0322-2000 High frequency electrocautery therapy instrument
Yy0448-2003 Ultrasonic Doppler fetal heart rate meter
Yy91079-99 Ecg monitor
Yy91090-99 ultrasonic therapy equipment
Yy91093-91094-99 intermediate frequency electrotherapy instrument
Assembly sequence of Medical equipment instrument connector:
1. Put the sheath, nut and cable clip on the cable in turn
2. Strip the wires according to the stripping requirements
3. Precoat the needle core with tin
4. Weld each wire core on the needle core according to the wiring definition
5. Insert the cable clip into the insulator fixing slot and protect the needle core
6. Install the housing
7. Tighten the plug nut and fasten the cable and plug tightly.You can thread the glue: DP190